Transient Voltage Surge Suppression for standard low speed data (13.5MHz max), communication and signal line protocols. Units provide protection against Transient Voltages that exceed the nominal operating voltage of incoming data. Each line is protected against surge current impulses up to 10kA.

The SLT device works in series with the communication lines being protected, diverting harmful transient energy while maintaining a tight clamp at the peak voltage. Units are designed to operate in a wide temperature range and are configured for EIA (Electronic Industries Association)protocols. The built in floating ground connection allows the device to provide protection at remote locations without creating a ground loop noise problem.

  • Solid state fail-safe design

  • Low shunt capacitance to reduce signal loss

  • Performance tested to verify compliance

Unit provides protection against Transient Voltages that exceed nominal operating voltages of incoming data. Each line is protected against surge current impulses up to 10kA.
Utility
Commercial
Industrial
Data/Comm

Data/Comm

3D Preview

Load Current
Max Surge Current (8/20) Iₘₐₓ
Short-Circuit Current Rating (SCCR)
Repetative Impulse Rating (Iₙ)
On/Off Status⬥
Housing Rating
Product Weight
Product Dimensions
Most Current Industry Standards
Surge Technology
Connector Form/ Type
Connector Method
Interface
Operating Temperature
Operating Frequency
Fusing
Listings & Certifications
Enclosure
Max. Operating Voltage
Max. Clamp Voltage
Energy Rating/ Wire
Response Time
Warranty
Series Resistance
Peak Pulse Power
Line - Load Sensitive
Breakover Voltage: (Line - Ground)
Attenuation Margin
NEXT
Data Transfer Rate
Power Sum NEXT
Return Loss
ACR
Power Sum ACR
ARC -F
PSACRF
Mounting
Relative Humidity
Terminals
Max. Circuits Protected
Modes of Protection
Continuous Current
Follow Current
Wire Range
Feedback
Remote Alarm Contacts
Remote Alarm contact capability (Nominal Volts/ Nominal Amps)
Remote Alarm Wire Size
Included Accessories
400 mA
10 kA per wire
[See EDR Series]
14 Ounces
ANSI/UL 497B
MOV, SAD
Terminal
Terminal Strip Screw
-40 ℉ to +185 ℉ (-40 ℃ to + 85 ℃)
Up to 50Mhz
Listed to ANSI/UL 497B
Plastic (ANSI/UL Rated 94 5V)
1.5 to 270 V DC
7.5 - 220 V available
< 1 Nanosecond
10 Year Limited Product Warranty
2.7 Ohms (nominal)
35mm DIN or panel mount via 2 integrated tabs that accept up to #6 sized screws
95% noncondensing
DIN Clip Kit

Specifications

Specification
Value
Load Current
400 mA
Max Surge Current (8/20) Iₘₐₓ
10 kA per wire
Housing Rating
[See EDR Series]
Product Weight
14 Ounces
Most Current Industry Standards
ANSI/UL 497B
Surge Technology
MOV, SAD
Connector Form/ Type
Terminal
Connector Method
Terminal Strip Screw
Operating Temperature
-40 ℉ to +185 ℉ (-40 ℃ to + 85 ℃)
Operating Frequency
Up to 50Mhz
Listings & Certifications
Listed to ANSI/UL 497B
Enclosure
Plastic (ANSI/UL Rated 94 5V)
Max. Operating Voltage
1.5 to 270 V DC
Max. Clamp Voltage
7.5 - 220 V available
Response Time
< 1 Nanosecond
Warranty
10 Year Limited Product Warranty
Series Resistance
2.7 Ohms (nominal)
Mounting
35mm DIN or panel mount via 2 integrated tabs that accept up to #6 sized screws
Relative Humidity
95% noncondensing
Included Accessories
DIN Clip Kit

Diagrams 

Not To Scale

Electrical Ratings

Click on any SLT Series model from the table to request a quote

Model Number
Service Voltage
TYPE
MAX # Wires
Protocol
SLT-XM-04-S-U-CL1-TS
30Vdc
DC
4
Closed Loop
SLT-XM-04-S-U-CL2-TS
55Vdc
DC
4
Closed Loop
SLT-XM-04-S-U-DC1-TS
95Vdc
DC
4
DC Power
SLT-XM-04-S-U-DC2-TS
130Vdc
DC
4
DC Power
SLT-XM-04-S-U-DC3-TS
195Vdc
DC
4
DC Power
SLT-XM-04-S-U-DC4-TS
18Vdc
DC
4
DC Power
SLT-XM-04-S-U-DC5-TS
140Vdc
DC
4
DC Power
SLT-XM-04-S-U-SL1-TS
25Vac
AC
4
Signal Line
SLT-XM-04-S-U-SL2-TS
10Vac
AC
4
Signal Line
SLT-XM-04-S-U-SL3-TS
270Vac
AC
4
Signal Line
SLT-XM-04-S-U-SL4-TS
45Vac
AC
4
Signal Line
SLT-XM-04-S-U-SL5-TS
50Vac
AC
4
Signal Line
SLT-XM-10-S-U-CL1-TS
30Vdc
DC
10
Closed Loop
SLT-XM-10-S-U-CL2-TS
55Vdc
DC
10
Closed Loop
SLT-XM-10-S-U-DC1-TS
95Vdc
DC
10
DC Power
SLT-XM-10-S-U-DC2-TS
130Vdc
DC
10
DC Power
SLT-XM-10-S-U-DC3-TS
195Vdc
DC
10
DC Power
SLT-XM-10-S-U-DC4-TS
18Vdc
DC
10
DC Power
SLT-XM-10-S-U-DC5-TS
140Vdc
DC
10
DC Power
SLT-XM-10-S-U-SL1-TS
25Vac
AC
10
Signal Line
SLT-XM-10-S-U-SL2-TS
10Vac
AC
10
Signal Line
SLT-XM-10-S-U-SL3-TS
270Vac
AC
10
Signal Line
SLT-XM-10-S-U-SL4-TS
45Vac
AC
10
Signal Line
SLT-XM-10-S-U-SL5-TS
50Vac
AC
10
Signal Line

*NOTE: Installation is accomplished by simply inserting the Protector in series with the communication cable(s) and connecting the grounds as required.

Replace X with: A for SAD Arrays, C for 5kA (Commercial), I for 10kA (Industrial) S for Solid State.

Compatibility Table

EDR Model Number
PVA50-1P-xxxv-S
PVA50-2P-xxxv-S
PVA50-3P-xxxy-S
PVA50-5P-xxxy-S
DRA50-1Pxxx-S
DRA50-2Pxxx-LGN
DRA50-2Pxxx-S
DRA50-3Pxxx-S
DRA50-3PSxxx-S
DRA50-4Pxxx-S
CLT-xxx
SLT CAT X/X-POE
SLT/XM-02-
SLT/XM-04-
SLT/XM-06-
SLT/XM-10-
TST010/XXX
TST020/(120-250v)
TST020/(24-48v)
TST040/XXX
bottom of page