top of page

SST Series

4-20mA Loop Surge Protection Device

Transient Voltage Surge Suppression for discrete signaling 4-20mA protocols. Units provide protection against Transient Voltage that exceeds the nominal signaling voltage. Each line is protected against surge current impulses up to 10kA.

The SST Series is configured to work in series with the measurement/control lines being protected, diverting harmful transient energies while maintaining a tight clamp at the peak voltage. SST Signaling units protect 1 circuit consisting of 2 wires (1 pair) plus ground.

Units are designed to operate in a wide temperature range and are ideal for the protection of 4-20mA current loop transducers, and similar instrument/control applications.

Consult the factory with any special package and circuit performance requirements.

The SST Series provides protection against Transient Voltages that exceed nominal operating voltages of incoming data. Each line is protected against surge current impulses up to 10kA
Commercial
Industrial
Residential
Power

Power

Data/Comm

Data/Comm

3D Preview

Load Current
Max Surge Current (8/20) Iₘₐₓ
Short-Circuit Current Rating (SCCR)
Repetative Impulse Rating (Iₙ)
On/Off Status⬥
Housing Rating
Product Weight
Product Dimensions
Most Current Industry Standards
Surge Technology
Connector Form/ Type
Connector Method
Interface
Operating Temperature
Operating Frequency
Fusing
Listings & Certifications
Enclosure
Max. Operating Voltage
Max. Clamp Voltage
Energy Rating/ Wire
Response Time
Warranty
Series Resistance
Peak Pulse Power
Line - Load Sensitive
Breakover Voltage: (Line - Ground)
Attenuation Margin
NEXT
Data Transfer Rate
Power Sum NEXT
Return Loss
ACR
Power Sum ACR
ARC -F
PSACRF
Mounting
Relative Humidity
Terminals
Max. Circuits Protected
Modes of Protection
Continuous Current
Follow Current
Wire Range
Feedback
Remote Alarm Contacts
Remote Alarm contact capability (Nominal Volts/ Nominal Amps)
Remote Alarm Wire Size
Included Accessories
400 mA
10 kA per Wire
ANSI/UL 497B
SAD GT
Hardwired
-40 ℉ to +185 ℉ (-40 ℃ to + 85 ℃)
Stainless Steel 316L ½” NPT
30 - 70 VDC Max
< 1 Nanosecond
15 Year Limited Product Warranty
2.7 Ohms per Wire/Line
1500W
Yes
36-82 V
95% noncondensing
L-L and L-G
#16 AWG Tinned Copper Wires

Specifications

Specification
Value
Load Current
400 mA
Max Surge Current (8/20) Iₘₐₓ
10 kA per Wire
Most Current Industry Standards
ANSI/UL 497B
Surge Technology
SAD GT
Connector Method
Hardwired
Operating Temperature
-40 ℉ to +185 ℉ (-40 ℃ to + 85 ℃)
Enclosure
Stainless Steel 316L ½” NPT
Max. Operating Voltage
30 - 70 VDC Max
Response Time
< 1 Nanosecond
Warranty
15 Year Limited Product Warranty
Series Resistance
2.7 Ohms per Wire/Line
Peak Pulse Power
1500W
Line - Load Sensitive
Yes
Breakover Voltage: (Line - Ground)
36-82 V
Relative Humidity
95% noncondensing
Modes of Protection
L-L and L-G
Wire Range
#16 AWG Tinned Copper Wires

Diagrams 

Not To Scale

Electrical Ratings

Click on any SST Series model from the table to request a quote

Model Number
Service Voltage
VPR
Application
SST/CP-020-UCL1-WL/CA
24V
24V
4-20mA Loop
SST/CP-020-UCL1-WL/FT
24V
24V
4-20mA Loop
SST/CP-020-UCL2-WL/CA
48V
48V
4-20mA Loop
SST/CP-020-UCL2-WL/FT
48V
48V
4-20mA Loop

Available Wire Sizes: 14 AWG, 16 AWG (Standard), 18 AWG and 20 AWG

Available Ground Wire Sizes: 16 AWG (Standard) and 18 AWG

Compatibility Table

EDR Model Number
PVA50-1P-xxxv-S
PVA50-2P-xxxv-S
PVA50-3P-xxxy-S
PVA50-5P-xxxy-S
DRA50-1Pxxx-S
DRA50-2Pxxx-LGN
DRA50-2Pxxx-S
DRA50-3Pxxx-S
DRA50-3PSxxx-S
DRA50-4Pxxx-S
CLT-xxx
SLT CAT X/X-POE
SLT/XM-02-
SLT/XM-04-
SLT/XM-06-
SLT/XM-10-
TST010/XXX
TST020/(120-250v)
TST020/(24-48v)
TST040/XXX
bottom of page